Seamaty SC200 fuses chemiluminescence’s high sensitivity with microfluidic precision, a POCT immunoassay analyzer built for routine clinical needs. It delivers lab-grade results in 12 minutes from 100μL of sample, supports 6 concurrent tests, and adapts to diverse settings—from ICU to primary care—with seamless, low-maintenance workflows.

Routine Immunoassay: Non-Negotiable Clinical Requirements

Routine immunoassay testing is a cornerstone of diagnosis and patient management across acute and chronic care. Clinical laboratories and care settings universally demand systems that meet four core criteria: rapid result turnaround, minimal sample input, intuitive operation and reliable accuracy—all while fitting practical daily workflow needs. Traditional benchtop immunoassay analyzers often fall short on portability, speed or ease of use for on-site and low-to-medium throughput settings, creating gaps for point-of-care solutions like the SC200.
The Seamaty SC200 is engineered to fill these gaps, aligning perfectly with the real-world immunoassay demands of diverse clinical environments, from busy emergency departments to small primary care clinics.

SC200: Key Advantages vs. Traditional Immunoassay Analyzers

A core strength of the SC200 is its ability to outperform traditional benchtop immunoassay analyzers in practicality and adaptability, without compromising on laboratory-grade accuracy. The table below highlights its competitive edge across critical performance and operational metrics:

Comparison Dimension Seamaty SC200 Traditional Benchtop Immunoassay Analyzer
Sample Volume 100μL (0.1cc) of whole blood/serum/plasma 200–500μL; serum/plasma only (no whole blood)
Test Turnaround Time 12 minutes per run 30–60 minutes per run
Max Throughput 6 samples per run (dual independent channels) 10–20 samples per run (bulky, fixed station)
Net Weight 6kg (compact, tabletop) 20–50kg (large benchtop/floor model)
Sample Pre-Processing None; direct testing Centrifugation/extraction required
Operation 4-step fully automated; no dedicated staff Complex multi-step; trained lab technicians only
Maintenance Low (single-use rotors, no easy-wearing parts) High (fluidic system cleaning, regular part replacement)
Portability Tabletop design; suitable for on-site testing Non-portable; fixed lab use only
Real-Time QC Built-in system (ensures accuracy) Separate QC steps; manual calibration

SC200 Core Technical Specifications

For seamless integration into daily clinical operations, the SC200 features robust, user-centric technical specs that balance performance and practicality—all validated to meet laboratory-grade standards:

Sample Type Whole blood, serum, plasma (no pre-processing)
Sample Volume 0.1cc(100μL)
Testing Time 12 minutes per run
Testing Principle Chemiluminescence + advanced microfluidic technology
Testing Channels 2 independent dual channels
Max Throughput 6 samples per run
Quality Control Real-time QC system (lab-level accuracy)
Net Weight 6KG
Reagent System Single-use reagent rotors (no cross-contamination)
Operation Mode Fully automated 4-step process
Maintenance No easy-wearing parts; minimal upkeep

SC200 Comprehensive Test Menu

The SC200 offers a tailored test menu for the most common immunoassay needs in routine clinical care, covering cardiac and inflammatory markers—two of the most critical categories for acute and chronic disease management. It also supports combination panels for streamlined multi-marker testing:

Test Category Key Markers Combination Panels
Cardiac Markers hs-cTnl, CK-MB, MYO, D-Dimer, BNP Cardiopulmonary combination panels
Inflammatory Markers PCT, IL-6, CRP, SAA Inflammatory response combination panels

SC200 Clinical Application Scenarios & Adaptive Advantages

Designed for universal routine use, the SC200 fits seamlessly into six key clinical settings, with tailored advantages that address each environment’s unique workflow and diagnostic needs:

Clinical Setting Core Immunoassay Testing Needs SC200 Adaptive Advantages
Cardiology/Chest Pain Center Rapid cardiac marker testing for MI/chest pain triage 12-min results; whole blood testing; cardiac combination panels
Pulmonary & Critical Care Medicine Inflammatory/cardiopulmonary marker monitoring Dual channels; real-time QC for critical care accuracy
ICU/Emergency Fast, on-site testing for acute patient triage Compact design; no pre-processing; low maintenance
Primary Care Routine inflammatory/cardiac screening Intuitive operation; small sample volume; tabletop size
Oncology Inflammatory marker monitoring for treatment response Reliable QC; single-use rotors (no cross-contamination)
Clinical Laboratory Low-to-medium throughput routine immunoassay 6-sample throughput; dual channels; easy data integration

Effortless 4-Step Fully Automated Operation

The SC200’s workflow is engineered for maximum efficiency in busy clinical environments, requiring no specialized lab training and eliminating manual errors. Its 4-step sector rotor operation is fully automated, ensuring consistent testing every time:
  1. Add Sample: Pipette 100μL of whole blood/serum/plasma to the rotor (no pre-processing).
  2. Place Rotor: Set the loaded rotor into the SC200’s designated slot.
  3. Insert Rotor: Push the rotor into the analyzer—automatic testing initiates immediately.
  4. Read Results: Lab-grade results are available in 12 minutes, with no post-test cleanup needed.

Low Maintenance & Cost-Effective Daily Operation

A standout benefit of the SC200 for long-term clinical use is its minimal maintenance requirements and cost efficiency:
  • Single-use reagent rotors: Eliminate cross-contamination and the need for reagent storage/handling; no fluidic system cleaning.
  • No easy-wearing parts: No pumps, valves or delicate components that require regular replacement, reducing downtime and repair costs.
  • All-in-one design: Integrates testing, QC and result output in a single compact unit, with no additional equipment needed for routine use.

Why Choose the Seamaty SC200 for Routine Immunoassay Testing?

The SC200 is the only POCT chemiluminescence immunoassay analyzer that balances laboratory-grade accuracy with real-world clinical practicality. It addresses the biggest pain points of traditional immunoassay systems—slow turnaround, complex operation, high maintenance and limited portability—while delivering the reliable results needed for routine diagnosis and patient management.
Whether you need rapid triage testing in the ER, routine screening in primary care, or low-throughput testing in a clinical lab, the SC200 adapts to your workflow, not the other way around.

Product Reference & More Details

To explore the Seamaty SC200’s full capabilities, technical documentation and reagent options, visit the official product page: https://www.ploydia.com/medical-diagnostic/sc200-fully-automated-chemiluminescence-immunoassay-analyzer/
For inquiries about customization, reagent supply or partnership opportunities, contact the Seamaty global support team for tailored clinical solutions.